Commander Controller – User Guide

Setup, wiring, and the parameter reference for the AutoVent Commander (Curtain Commander) controller. Version v114.

8 output stages
Curtains, fans & sprinklers
Rain & wind ready
Effective temperature

AutoVent Curtain Commander controller in a clear weatherproof enclosure with a red LED display reading 80, four curtain output sections labeled Curtain #1 through Curtain #4 with toggle switches

Electrician’s guide overview

This user’s guide is for the installation and use of the Curtain Commander system. Thank you for purchasing the Curtain Commander System. The Curtain Commander is designed for easy installation and operation. The system controls 8 stages of curtains, fan or sprinklers.

AutoVent power supply box for DC curtain motors
Power supply for DC curtain motors.

Main features

The Curtain Commander System is designed for the unique challenges of livestock facilities.

  • Controls up to four individual curtains, or up to 6 fans or 8 sprinkler zones
  • Each of the curtain circuits has its own temperature setting.
  • Has adjustable open and shut temperature.
  • Rain sensors for two curtains circuits. (Optional)
  • Has toggle switch overrides for all output relays
  • Effective temperature compensation
AutoVent rain sensor with a clear domed top
The optional rain sensor.

Installing the Commander

Consider the following before installing the Curtain Commander System:

  • Protect the enclosures from moisture-mount them in a secure and dry place.
  • Place the system where cows are not able to come in contact with them.
  • Important: Only drill holes in the bottom of the enclosures.
Warning: Drilling holes into the top of the enclosures voids the warranty.

Supplying power to the Commander

Power the system with 120 VAC as shown in the picture below. Installing surge protection back at breaker panel is recommended.

Photo of the Curtain Commander 120 VAC power supply terminal block with the line and neutral wires landed
Power the system with 120 VAC at the supply terminals.

Installing and wiring the temperature sensor

Placing the temperature sensors

Place the temperature sensor in the middle of the barn or in a location which represents the barns average temperature.

Note: It is important to not allow sensors to come into contact with direct sunlight.

Extending the temperature sensor

The sensor that’s included is 10 feet long. If you extend it, do the following:

  1. Run a length of 18–24 AWG wire (twisted or shielded if possible) from the temperature sensor to the Curtain Commander. Keep the sensor wire away from high voltage wire by at least 1 foot.
  2. Solder or use gel filled crimps to connect the wires to the temperature sensor.
  3. After connection is complete, make sure it is waterproof.
  4. Connect the temperature sensor to the Curtain Commander as shown below:
Curtain Commander terminal block diagram with an arrow labeled Connect temperature sensor here pointing to the Temperature Sensor #1 terminals, alongside the 24 vdc and Rain sensor #1 and #2 terminals
Connect the temperature sensor to the Temperature Sensor #1 terminals.

Installing the rain sensors

Rain sensors are optional. Each curtain has a rain sensor input. A curtain will close when it’s sensor detects rain.

Decide location of rain sensor

The curtain closes whenever its rain sensor detects precipitation. The location/height of the rain sensor compared to your eave, is the rain response mechanism. Do the following steps to determine where to mount the sensor.

  • Visualize rain falling straight down from the edge of the eve.
  • Visualize wind beginning to blow the rain towards the sidewall.
  • As wind increase, it blows the rain in the barn at an increasing height.
  • Decide at what height the rain is unacceptable.
  • Mount the sensor at that height, with the sensor tilted slightly away from the barn.

If bedding or other debris can accumulates on the sensor, it may not work until its gets washed off.

Diagram of a barn sidewall post showing the rain sensor for the top curtain mounted higher and the rain sensor for the bottom curtain mounted lower, with rain blowing in from a cloud and arrows marking less sensitive to blowing rain at the top and more sensitive lower down
Mount the sensor higher for less sensitivity to blowing rain, lower for more. Tilt it slightly away from the barn.

Rain sensitivity adjustment

The sensor has 4 sensitivity settings. Dip switches 1 & 2 set the rain detect threshold.

Photo of the round green rain sensor circuit board with an 8-position DIP switch bank and the color-coded sensor wires landed on the blue terminal block
The DIP switch bank inside the rain sensor.
Rain sensor DIP switch table
SwitchSetting
1Sensitivity – default off
2Sensitivity – default ON
3off-On
4must be off
5must ON
6must be off
7must be off
8must be off

Sensitivity settings (switches 1 & 2)

Rain detection thresholds
Switch 1Switch 2ThresholdNotes
offoffFirst drop detectionVery sensitive; will be on at first drop of rain. Our experience is this will close a curtain too quickly. False alarms.
onoff.1 inch per hourSensitive. Maybe about right for some calf buildings or if you have manure solids bedding inside the curtain.
offon.25 inch per hourModerate response. This works well for most dairy curtain applications.
onon1 inch per hourThis will have your stall beds wet.

15 minute delay after it stopped raining: Normally the curtain needs to reopen after it stopped raining. If you want it to stay closed for a while after the rain, set dip switch 3 on. Normally we want #3 off, so curtains re-open as rain stops.

Connecting the rain sensor to the Commander

The rain sensors come with a connector and a 3ft pigtail. 50 0r 100 foot extensions can be purchased. Alternatively, regular 18 awg can be used to extend the sensor.

Route the sensor’s wire at least one foot away from 120 volt (or higher) wires.

Locate the rain sensor terminal block inside the Curtain Commander. It has four terminals marked Blue, Black, Brown, and White. Connect the cord to rain sensor terminals as per wire color marked on the rain sensor terminal block.

Curtain Commander board diagram with the Rain sensor #1 and Rain sensor #2 terminal groups circled and labeled Connect the rain sensor for curtain #1 here and for curtain #2 here, plus the Sensor #3 and Sensor #4 input and ground terminals
Connect the rain sensor for curtain #1 and curtain #2 at the marked terminal groups.

Connecting the 3rd & 4th rain sensors

The 3rd & 4th sensor terminals do not provide power due to space limitations on the board. To wire the 3rd and 4th rain sensors, connect the brown (ground) and white (input) wires to the corresponding 3rd and 4th sensor terminal and the black (24v) and blue (ground) wires to sensor terminal #1.

Multiple curtains on a single rain sensor

Multiple curtains can be operated from a single sensor. To get satisfactory performance, the curtains should be on same side of the building. Combining top and bottom curtains gives unsatisfactory performance in dairy applications.

To connect multiple curtains: Jump the white (input) wire between all curtains that share the sensor.

11/8/21: With V11.4 or higher, you can assign any curtain to a particular rain sensor with C26 to C29. No wire jumping required. If you have several curtains to same sensor, set the closing sequence with C21 to C24.

Troubleshooting & wire color terminology

The rain sensor is prewired with color coded pigtail. Wire colors function as follows:

Blue = 24vdc
Black = ground
Brown = signal ground
White = input signal to controller

When it senses rains, the sensor will connect Brown & white together. The controller will display R1 or the respective sensor number, when its input circuit is closed/raining.

To show if sensor is working, the sensor has Green light in center of its clear dome. It will illuminate when it detects rain. To tell if sensor is working, dump water on it, then rub it with wet hands. You will be able to hear it click and see the green Led as soon as it detects rain.

If it does not nothing, make sure there 24vdc between blue & black at the sensor.

Installing the humidity sensor

The humidity sensor allows you to open curtains or start fans when it gets real humid.

Where do I mount the humidity sensor?

Mount it near center of building, but not where it will get sprayed with water. Spraying it with water will give inaccurate readings.

Wiring the humidity sensor

The humidity sensor is prewired with a M12 connector. M12s always has the same wire colors and pin positions.

Blue wire → 24vdc+ (power)
Black wire → Sensor #2 + (sensor input to controller)
Humidity sensor wiring diagram showing the black wire to Sensor #2 plus and the blue wire to 24 vdc plus on the Curtain Commander board, with the hatched humidity sensor module at right
Humidity sensor wiring to the Curtain Commander board.

You can purchase additional extension cables from your dealer.

Tech note: The HD8 board’s AN1 jumper must be set to I (center position).

Installing the curtain motor load sensor

The optional curtain motor load sensor monitors the amp load of each motor. By monitoring the amps of the hot wire for the curtain motor power supply, it calculates the amp draw for the motors.

Wire the signal wires with 18 to 24 awg as shown below.

Wire the power to the curtain motor power supply as shown below. Neutral or L2 does not go through the amp meter. Go directly to curtain motor power supply after you went through the amp meter. Do not power anything else after the amp meter, or it will cause inaccurate amp readings.

Wiring diagram for the curtain motor load sensor showing 18-24 gauge signal wires from the Curtain Commander board, the amp sensor with 2 passes for 120 volt and 4 passes for 240 volt, the curtain motor power supply, and the breaker panel
Install the amp meter on Hot or L1 for 240 volt. Pass the 120 hot wire through twice; for 240 volt, pass L1 through 4x.

Installing the windmeter

The windmeter shuts the fans off when it is windy outside. Mount the windmeter up above the roof or inside the building. If you mount it inside, make sure the fans will not affect it.

Wire the wind meter as shown in diagram. Polarity is not important.

The screens left most decimal point is the windmeter indicator light. The leftmost decimal point will blink as the windmeter rotates. The blinking decimal point is how you verify the windmeter is connected correctly.

Windmeter wiring diagram showing a three-cup anemometer connected to the Wind wheel terminals on the Curtain Commander board, alongside the Temperature Sensor #1, Sensor #2, 24 vdc, Input #4 and Rain sensor terminals
Wire the anemometer to the Wind wheel terminals. Polarity is not important.

Wiring curtain motors

The Curtain Commander System was designed to allow multiple curtain motors to be easily wired. The curtain motors switch on one at a time. This allows multiple motors to be wired from a single power source.

DC motors

The following schematic shows how to wire multiple DC curtain motors.

DC motor schematic showing relay outputs 8 down to 1 wired to four DC curtain motors, each labeled reverse leads to swap direction, fed from the Purple DC minus and Brown DC plus from the DC power supply, with a note 10 amps max per relay
DC motor schematic. Reverse a motor’s leads to swap direction. 10 amps max per relay.

AC curtain motors

The even numbered relays are energized for Close and odd numbered relays are energized for OPEN.

Note: If the curtain motor is more than .3 HP use a contactor to switch the curtain motor current.
AC curtain motor wiring diagram (Figure 1-10-2) showing relay outputs 8 down to 1 with common, NC and NO contacts wired to AC curtain motor #1 and motor #2 with open and close lines and an AC power source
Figure 1-10-2. Even relays energize for Close, odd relays for Open.

Relay testing & electrician checklist

Curtain motors troubleshooting

“The curtain motors do not run”

  • For 24 VDC curtain motors the power supply fuse may have blown. Check the fuse in the curtain motor power supply box.
  • Check if there is voltage coming from the power supply.
  • For AC curtain motors, check the fuse breaker supplying the curtain motors.
  • A relay may be burned out.

Other possible issues

“An output relay seems burned out” The output relays can burn out and still show their indicator light on. Swap relays to see if you can replicate the problem in another circuit. Replace relays with Magnecraft 24 vdc coil 781 series.

Troubleshooting the relays

You can verify if the controller and its wiring by using the relay board diagnostics. The diagnostics allow you to turn the relays on one at a time via the keypad. This is so we can tell if toggle switches and other components are working.

To turn the relays on via the keypad:

  1. Turn power off to the Commander, wait 10 seconds.
  2. Press the Down while repowering the Commander.
  3. The screen will now show 01. This means relay #1 is selected.
  4. Press Enter to turn the relay on. Press UP/Down to select other relays.

Output relay testing

The output relays in the Curtain Commander System can be manually activated. This function allows the ventilation equipment to be tested and operated even if the controller is not powered (curtain power supply must still be powered).

Manually operating an output relay: To operate manually, press and hold on the green button. Release when curtain is at desired position.

Photo of a plug-in output relay with the green manual test button on its front
Press and hold the green button to operate an output relay manually.

Latching output relays in an emergency

Electrician checklist

Before continuing to the next section and after all the wiring is complete, the electrician should do the following:

  1. Double check all curtain motor limit switches.
  2. Label all the toggle switches with what is being controlled and where in the barn the equipment is mounted.

Relay size

Relay size: The Curtain Commander relays are not intended to switch 1/2 HP or larger motors. Use an external contactor when controlling these larger loads.

Overview of the screen and buttons

The temperature is displayed on the screen whenever the parameters are not being assessed. The figure below shows that its 60°. If a rain sensors is connected and is sensing rain, the screen will blink P1 for curtain #1 or P2 if it is sensing rain for curtain #2.

The screen will blink E-1 thru E-4, if a curtain motor tripped the electronic overload. E-1 is for 1st motor, E-2 is for 2nd motor. Press Enter to clear.

Curtain Commander display showing 60 in seven-segment digits with round Down, Enter and Up buttons below
The display reading 60°, with the Down, Enter, and Up buttons.

Why does my temperature flash sometimes? The screen will flash the Effective temperature when its activated. Effective temperature is automatically activated when controller thinks its been extra hot.

Parameters

There are several parameters that you can change. The parameters are labeled P1, P2…. These parameters are the curtain’s temperature setpoints and cycle time.

Viewing and changing parameters

To view the first parameter press Enter. The screen now alternates between P1 and parameter 1 setpoint. To increase or decrease the set point press UP or Down. Press enter to scroll to Parameter 2. By pressing Enter you can scroll through the remaining parameters. After you have reached the last parameter, the screen displays End and then reverts to displaying the temperature.

Curtain parameters

Understanding curtain temperature parameters

The temperature setpoint for each curtain controls when the curtain opens. If the temperature is warmer than the setpoint the curtain will slowly open. The temperature must drop several degrees below the setpoint before the curtain will slowly close. The temperature deadspan controls how much the temperature must drop before the curtains begin to close.

Understanding curtain cycle time

The curtains use a cycle to control how fast they respond to temperature changes. The cycle consists of On seconds and wait minutes. The curtain switches on for P6 seconds and then waits for P7 minutes then repeats the cycle. Adjust the cycle time so the curtain takes approx one hour to fully open or close.

Curtain parameters
IDDescriptionDefaultMinMax
P1Curtain #1 temperature setpoint.60°1°99°
P2Curtain #2 temperature setpoint.60°1°99°
P3Curtain #3 temperature setpoint.60°1°99°
P4Curtain #4 temperature setpoint.60°1°99°
P5Seconds the curtain is switched on.10550
P6Minutes the curtain waits until it is switched on again when its opening (see P16).5225
P7Temperature difference between opening and shutting the curtain. If the deadspan is 5.0° and the curtains setpoint is 38°, the curtain will jog close when the temperature is 33° or less.5.0°1.0°20.0°
P8Curtain #1 maximum amps. .5125
P9Curtain #2 maximum amps. .5125
P10Curtain #3 maximum amps. .5125
P11Curtain #4 maximum amps. .5125
P16Minutes the curtain waits until it is switched on again when its closing. 0 = same as P6.149

Understanding the amp overload

If your screen is flashing E-1 thru E-4 one of your curtains is tripped the amp overload. The amp overload stops a motor if it goes too hard. This curtain will not go again from temperature until you clear it. The remaining curtains will continue working.

Even if a curtain is overloaded you can force it by using the toggle switches. Take care when doing this.

By forcing a curtain you maybe able to figure out the problem. Force it to go open. While its running, watch the amp reading on the screen. If it spikes near the top, the top limit is not set correctly.

My curtain overloads all the time. However the curtain still moves. If a curtain overloads every couple of days or less, you may have a problem. It could be the limit switch on the motor is not stopping curtain until its wrapped too tight. Or a rope, strap or weeds are wrapped in the curtain.

My curtain overloads quickly. Curtain does not move. You curtain motor maybe bad. Also check for damaged cords around the motor.

Tech note: The controller does not consider the motor overloaded the first time the amps spike above the curtain’s setpoint. It will try multiple times. It tries multiple times until it decides the motor is overloaded for real. Default is set to try twice. Example: If curtain tries to go open, and takes too may amps twice the curtain will be overloaded for Open. After a while the curtain may try to close, if the motor can jog close, it will clear the overload. Now the curtain can go open again.

Controlling the rain sensor

The rain sensor closes the curtains when rain is sensed on the sensor element. You control how much rain shuts the curtain by the location the sensor is mounted and by adjusting the sensitivity knob inside the rain sensor. Anytime rain is sensed the curtain will close for a maximum of approx 3 minutes [parameter C3]. As soon as the rain is no longer sensed, the curtain will try to reopen.

Humidity logic for the curtains

If you have a high humidity, you can a curtain open automatically. It will open then wait until humidity drops. How far open the curtain goes when its too humid, is set with P13. The display will blink H1 … H4 when to show you which curtain has responded to humidity. If you want humidity off when it gets too cold, P14 disables the humidity logic. Only 1 curtain will respond to humidity, select desired curtain with P15.

Curtain humidity parameters
IDDescriptionDefaultMinMax
P12Maximum humidity for the curtain.80 RH%199
P13Seconds the curtain will open when it gets to humid.30199
P14Too cold for humidity. Low temperature cutoff.32°  
P15Humidity curtain. The curtain that will respond to humidity.304
To activate the humidity sensor on you system, the 2nd sensor type parameter C11 needs to be set to 1.

Configuration parameters

There are several configuration parameters which change the way the controller operates. To access the configuration menu, remove the power from the controller and repower while pressing Enter.

Configuration parameters
IDDescriptionDefaultMinMax
C1Number of curtains for this controller. 04
C2Number of fan banks for this controller. 06
C3Number of sprinkler circuits for this controller. 08
C40 = Fahrenheit, 1 = Celsius.001
C5Max seconds the curtain will close when the curtain senses rain.18010255
C6MPH deadspan for fans.3.51.025.5
C7Wind minutes, minutes included in windspeed reading.315
C8Wind meter calibration.25160
C9If fan bank #1 uses duty cycle.NoNoYes
C10If fan bank #2 uses duty cycle.NoNoYes
C11Type of 2nd sensor connected. 0 = none, 1 = humidity, 2 = amp meter, 3 = 2nd temperature sensor.2  
C12If sprinklers use Effective temperature.YesNoYes
C13If the 0-10v option is installed.NoYesNo
C14Start seconds for curtain motors.2.00.110.0
C15Extra amps for motors during start seconds.150%  
C16How often a curtain must overload until it is disabled (overloaded).219
C17Amp meter multiplier, 1.0 = 10 volt from amp sensor = 20 amps.1.0  
C18Amp meter averaging. How many internal readings are averaged, so you have a more stable amp number. Higher = more stable but slower reacting.81255
C19(Only active if there is a 2nd temperature sensor) How many curtains will use the 2nd sensor starting with curtain #1.004
C21When raining, which curtain must close before curtain #1 may close.004
C22When raining, which curtain must close before curtain #2 may close.004
C23When raining, which curtain must close before curtain #3 may close.004
C24When raining, which curtain must close before curtain #4 may close.004
C26Rain sensor for curtain #1.013
C27Rain sensor for curtain #2.023
C28Rain sensor for curtain #3.033
C29Rain sensor for curtain #4.033

Note: the row between C19 and C21 is labeled “Future” in the manual.

Fans

The controller operates up to 6 banks of fans. You adjust the temperature for each bank separately. These fans use the controller’s Effective Temperature. The Effective temperature is a simple calculation that makes the fans operate more during hot weather. You can adjust the Effective temperature calculation too.

You can optional connect a wind sensor to the controller. Then you can have your fans automatically turn off when its really windy outside.

Fan parameters
IDDescriptionDefaultMinMax
P20Fan #1 starting temperature.*60°1°120°
P21Fan #2 starting temperature.62°1°120°
P22Fan #3 starting temperature.65°1°120°
P23Fan #4 starting temperature.67°1°120°
P24Fan #5 starting temperature.69°1°120°
P25Fan #6 starting temperature.71°1°120°
P26Fan #7 starting temperature.71°1°120°
P27Fan #8 starting temperature.71°1°120°
P28Fan deadspan. Temperature difference between turn on and off. If the deadspan is 3.5° and the fan starts at 65°, it will turn off at 62.5.3.5°1.0°20.0°
P29MPH at which the fans will turn off. With optional wind meter. If you have open sidewalls, and its really windy outside, you can save electric by having your fans turn off automatically.12360
P30Duty cycle, off minutes. (For cold weather ventilation**)2.0.125.5
P31Duty cycle, on minutes. (For cold weather ventilation**)2.0.125.5

*Note: All the fan banks use the Effective temperature, which can be warmer than ambient°. **Hidden if not used. The duty cycle will cycle a fan bank on and off, when fan would normally be off. The duty cycle can be applied to fan bank #1 or #2. See configuration menu to activate the duty cycle.

When should I start my fans?

Autovent has found lactating cows producing 100LB or more, can overheat when the night air stayed around 61° ambient. This was with cows laying in freestalls and no air movement. This was at 12;30 to 2:00 AM in the morning, after the fans turned off. At 59° and below they did not overheat. Cows in 60lb production did not overheat at night unless air temperature was approximately 72°. Please note humidity was high.

Variable speed fans

The controller’s variable speed output changes with the temperature. The hotter it gets, the faster it goes. You can adjust the {P35} minimum speed° and the {P36} full speed°.

When the fan will start°: Variable speed fans are usually connected to a circulating fan relay. The circulating fan relay will stop the fan when it gets too windy or cold. (Note: All fans run at same speed but can start at different temperatures.) The fans use the Effective temperature°, which is warmer than ambient° after a hot day.

Manually forcing the fan speed: For testing the fans, you can manually force it to a fixed speed {P38}. When P38 is set to 11, the speed varies with the temperature. Setting it between 1-10 will force the fans to run at a fixed speed, 1 = 10% 5 = 50%. You must remember to set it back to 11, so fans speed adjusts automatically.

Variable speed fan parameters
IDDescriptionDefaultMinMax
P35Begin accelerating temperature. When temperature° gets warmer than this, the fans begin to spin faster. Below this, the fans will spin at constant rate until their circulating fan relay turns off.60°1°120°
P36Full speed temperature. When temperature reaches this, the fan will be full throttle. Note: the speed ramps with the temperature. (It does not jump from low to full speed.)95°1°120°
P37Minimum fan speed, the slowest the fans will run, in % of full speed.15.0%1%100%
P38Manual override speed. This allows you to fix the fans speed indefinitely. Set it to 11 for automatic temperature control. Manualy force it to a fixed speed by setting it between 0-10. 0 is off and 10 is full speed.11 (auto)110

The variable speed output is a DC voltage that changes with your temp[erature settings. It varies between 0.1 to 10 volts. It is connected to a fan’s Variable frequency drive (VFD). The VFD reads this 0-10 volt signal to know how the speed. However the VFD also uses an additional start signal. The start signal connects to a circulating fan relay in the controller. The circulating fan relay needs to be on for the VFD to start. This allows you have different start temperatures for each fan via P20 to P25.

Sprinklers

The controller operates up to 8 sprinkler circuits. You adjust the temperature when they start spraying and how often it sprays. As it gets hotter it will spray more often. You can adjust all this.

Sprinkler parameters
IDDescriptionDefaultMinMax
P40Low /on temperature. Sprinklers turn on at this temperature.75°1°120°
P41The high temperature for sprinklers.95°1°120°
P42Dry off / interval minutes at low temperature.15.0.125.5
P43Dry off / interval minutes at High temperature.5.0.125.5
P44Sprinkler #1 sprinkle seconds at Low temperature.301255
P45Sprinkler #1 sprinkle seconds at High temperature.301255
P46Sprinkler #2-8 sprinkle seconds at Low temperature.301255
P47Sprinkler #2-8 sprinkle seconds at High temperature.301255

What sprinklers do

In this chapter we talk about sprinklers. In the dairy industry some people also call them soakers. Either way, in this chapter we assume they are the same thing.

Sprinklers are usually mounted above the feed bunk, pointed down towards the cows. Every so often they spray water at the cows. This cycling on and off allows the water to evaporate. This is the most effective way to use water to cool the cows.

Photo of overhead sprinklers spraying water down onto dairy cows standing along a feed bunk inside a barn
Figure 1: water spraying on the cows.

When should the sprinklers turn on?

The sprinklers are often turned on around 70°F. This default is a good temperature setting to start with. Parameter “P40 sprinkler low temp” controls when the sprinklers begin to cycle.

How much water should I spray on the cows

The idea of soakers is to spray water onto the cow until she is wet. You may wonder how do I know if she is wet enough? It is easy to determine this once you have your sprinkler system installed. You get a stopwatch and watch as the water is spraying. When she becomes saturated and the water begins to run off, that is the maximum wetness you can get. Record the length of time it took. You need to make sure that her udder is not getting wet. See the picture below for the proper wetness.

Close-up photo of a dairy cow's hindquarters and udder showing the udder area has been kept dry
The water has not wetted the cow’s udder.
Photo of a wet dairy cow standing in a barn, soaked along her back and sides but with the udder kept dry
Here you can see that the water has not wetted the cow’s udder. Soaking the cow but not her udder is the goal.

Often the time needed to wet the cow is approximately 30 seconds. This varies considerably by nozzle sizes and water pressure. The default setting is 30 seconds. Parameters P44-P47 allow you to adjust each sprinkler zones spray time. You can adjust the system to spray more water when its hotter. However, proper wetness does not vary significantly by temperature.

What is the dryoff time

The dryoff time is how long the controller waits until it may spray again. The cow is supposed to dryoff before she gets wet again. How quickly the cows dries off really varies with the temperature. As it gets warmer, your cows will dryoff sooner. To accommodate this, the default dryoff time ramps lower and lower as the temperature increases. This makes your sprinklers spray more often as the day gets warmer.

Adjusting dryoff: The dryoff time default is 15 minutes at 70° and 5 minutes at 90°. This is what AutoVent feels is a good number to begin using your system. However, if your cows are not drying in the default time, you can change it. To change the dryoff time, Parameter “P42” sets the 70° dryoff time. Parameter “P43” sets the 90° dryoff time.

Effective temperature°

When you have an extra hot day, and it cools at night, your cow needs extra time to cool down. For optimum production and breeding, the Commander calculates an effective temperature. The effective temperature is patterned after your cow’s body temperature. It makes your fans and sprinklers run longer after a hot day.

Effective temperature keeps a running average of the past 12 hours temperature readings. Then, if the average is above 75°, it assumes the cows need more time to cool. This assumption, adds 5° to the ambient temperature. This is the Effective temperature. The fans and sprinkler use it. You can adjust the 12 hours, the 75° and 5°.

  • P52 is the 75°, the temperature at which it assumes cows are overheated.
  • P53 is the 5°, how much the controller adds to the ambient°.
  • P54 is 12 hours, How many hours of temperature readings are being considered.
  • C12 allows you turn the effective temperature off for the sprinklers. (See configuration menu.)
Effective temperature parameters
IDDescriptionDefaultMinMax
P52Running average temperature at which controller assumes it has been extra hot.74°1°120°
P53Degrees added to ambient temperature to calculate Effective temperature.6°0°20°
P54Hours of temperature readings included in running average.12124

Heaters

You can use the Commander to turn heaters on and off.

Heater parameters
IDDescriptionDefaultMinMax
P60Heater #1 setpoint temperature.601°99°
P61Heater #2 setpoint temperature.6°0°20°
P68Heater hysteresis. A heater set to 75° with a 1.5° hysteresis will turn on at 75.0° and off at 76.5°.1.0.19.9

Update log

Version 10.2 (11-2012):

  • Input #4 is now programmed to be the rain sensor for curtain #4.
  • Wind wheel input automatically turns its self into curtain rain sensor connection #3, when C1 (number of curtains) is 4.
  • Changed display so it does not display effective temperature if there are zero fans or sprinklers.

V10.9: added heater logic. You can have up to 8 heaters.

V11.3: added Changed input #4 to be a output for a Solid state control for curtain motor power – disabled rains sensor #4.

V11.4 (11/20/21): added parameter for each curtain, so any curtain can be assigned to any rain sensor.